building science case studies
Explore our collection of building science resources, including project case studies, technical articles, and research studies.
Towards Development of a 1980’s Greater Hamilton Area
Single Detach Residential Housing Archetype:
Retrofitting to the Performance Levels of Net-Zero Energy Ready
This research defined attributes of existing residential housing in the Greater Hamilton Area for the development of an archetype model that would represent a two-storey single detached house to investigate the potential of the existing housing stock to achieve Net Zero Energy Ready performance.
The findings of this research supported the development of the first archetype model to represent the Greater Hamilton Area that identified retrofit strategies that can reduce the energy consumption of the existing single detached housing stock, while acknowledging solutions that ensured durability was preserved.
Production Builder Net Zero Energy Ready Home
The building enclosure and mechanical systems of this house were optimized to allow the roof area to supply enough solar energy to offset the energy consumed by the house on a yearly basis. This building practice is referred to as Net Zero Energy Ready, which allows a renewable energy source to be installed at a later date without the needed expensive alteration of the building enclosure or mechanical systems.
In addition to offering a lower energy consumption, due to the measures applied to the building enclosure and mechanical systems, the house will also offer the occupants consistent temperatures throughout all levels, have superior levels of durability compared to a building code constructed home, and allow the occupants to breathe fresh filtered air all year. This will result in a house that has exceptional energy performance, provides the occupants with the ultimate experience in comfort, and utilizing these building practices ensures the house will last generations, the definition of a Better Built Building.
Retrofit of Existing House
Improving comfort, durability, and reducing energy consumption.
The existing house was built in the 1980’s, which meant very little insulation in the building enclosure and zero attention to detail related to air sealing measures. This resulted in occupants experiencing cold surfaces (often complaining of feeling cold), rooms over heating in summer months, drafty rooms, infiltration of insects, and concealed moisture in the building enclosure (reduced durability). To improve the occupant experience an interior retrofit was applied that featured additional insulation, installation of a continuous air barrier to ensure air leakage was minimized as much as possible, and the replacement of the windows to triple glazed units that have a low solar heat gain coefficient.
The improvements to the building enclosure resulted in the elimination of cold surfaces, rooms no longer overheated in the summer months, drafts were gone and so to were the insects, and because the occupants engaged a building scientist the interior building enclosure retrofit was implemented to enhance durability (less moisture or potential for moisture in the building enclosure). With attention to detail and strategically placed insulation, existing houses can also achieve exceptional energy performance as well as provide the ultimate experience in occupant comfort.