One of the substantial inclusions into the compliance packages was the introduction of continuous insulation in walls above grade. When continuous insulation is required, it is referenced in the tables as “ci”. In Appendix A of SB-12, continuous insulation is defined as, “continuous insulation (ci) is intended to minimize the thermal bridges in an assembly. It is generally uninterrupted across all structural members. Exceptions to this include fasteners and service openings. Insulation may generally be installed on the interior or the exterior, or may be integral to any opaque surface of the building envelope. It may generally be made of various material such as board, blanket, sprayed or other types of insulation. Compressions such as blanket fasteners are permitted.”
Although the OBC has introduced continuous insulation, how does it benefit the walls above grade? By wrapping the walls above grade in a blanket of insulation it reduces thermal bridging at the framing members such as, top and bottom plates, and floor headers (Figure 1). This results in a reduction in heat gains or losses, which lowers the energy consumption of the building.


Figure 1: Two-storey House Without and With Continuous Exterior Insulation Above Grade Walls
(Thermal Bridging: Small Details with a Large Impact – Jay H. Crandell – ABTG / ARES Consulting)

Figure 2: Comparing Amount of Moisture in Various Dry Bulb Temperatures of Air
Visually this can be seen in Figures 3 and 4 when comparing a 2×6 R24 above grade wall assembly to a 2×6 R19 with R5 continuous exterior insulation wall assembly. The opportunity for the development of condensation can be significantly reduced with just an R5 continuous exterior insulation and almost eliminated with an R10 continuous exterior insulation (Figure 5). Note the calculation of potential condensation depends on the exterior temperature of the climatic location, interior temperature, and the interior relative humidity.



Figure 3: Controlling Cavity Temperature – 2×6 R24 Batt Insulation with Wood Sheathing (Toronto)
Figure 4: Controlling Cavity Temperature – 2×6 R19 Batt Insulation with R5 Continuous Exterior Insulation (Toronto)
Figure 5: Controlling Cavity Temperature – 2×6 R19 Batt Insulation with R10 Continuous Exterior Insulation (Toronto)
Often the question arises, “Does the permeance of the exterior continuous insulation matter in the context of affecting the assemblies’ durability?” The concern being does a low permeance exterior insulation combined with a low permeance interior sheet membrane (i.e. 6 mil. poly) create an opportunity for moisture to be trapped inside the above grade wall assembly. This concern was reviewed in the National Research Council (NRC) document, “Report on Properties and Position of Materials in the Building Envelope for Housing and Small Buildings”. Four geographical locations were reviewed that included Ottawa, Edmonton, Vancouver, and St. John’s and five types of exterior insulation with a thermal resistance of R4 were analysed that had vapour permeances of 2 ng/Pas•m2, 60 ng/Pa•s•m2 , 90 ng/Pa•s•m2, 300 ng/Pa•s•m2, and 1800 ng/Pa•s•m2. The findings concluded:
- More cavity insulation increases the risk potential for condensation at the exterior sheathing interface
- Exterior insulation reduces condensation risk potential at exterior sheathing interface
- No significant difference in condensation risk potential between the five insulations
These finding resulted in the National Building Code (NBC) of Canada lowering the trigger point for the inboard and outboard calculation to a vapour permeance of 30 ng/Pa•s•m2 for any exterior insulated sheathing. In conclusion, the research highlighted that the amount of thermal resistance outboard of the framed structure is a more important variable than the permeance of the exterior insulation (i.e. select enough exterior insulation to keep the first condensation surface above the dew point). Although the tested wall assembly in the NRC research report utilized an interior vapour retarder with a permeance rating of 60 ng/Pa•s•m2, good building science practice suggests that the assembly should be able to dry in at least one direction, which represents a margin of safety for the assembly should it become wet. Therefore, it is recommended to adjust the interior vapour retarder to a membrane that has a variable vapour permeance when the permeance of the exterior insulation is classified as low. If the moisture content behind the membrane were to increase, the vapour permeance of the membrane increases to allow the moisture to escape towards the interior.